Specification | |
Model | Cisco ISR4321 |
Product Number | ISR4321-K9 |
Form factor | Desktop |
Integrated WAN Ports | 2x10/100/1000 (WAN or LAN ) and 1G SFP |
Integrated Lan Ports | - |
Network Interface Modules (NIM) | 2 Slots |
Wireless Lan | - |
Performance | 50 Mbps |
Routing Protocol | RIP v1/v2, EIGRP, OSPF, BGP, PBR, PfR, OSPFv3, IS-IS, |
IPSec VPN | - |
Redundant power supply | - |
Specifications of Cisco 4000 Family Integrated Services Routers
Technical Specifications |
Cisco 4461 |
Cisco 4431 |
Cisco 4351 |
Cisco 4331 |
Cisco 4321 |
Cisco 4221 |
|
Aggregate Throughput (Default) |
1.5Gbps |
1 Gbps |
500 Mbps |
200 Mbps |
100 Mbps |
50 Mbps |
35Mbps |
Aggregate Throughput (Performance License) |
3Gbps |
2 Gbps |
1 Gbps |
400 Mbps |
300 Mbps |
100 Mbps |
75 Mbps |
Aggregate CEF Only[5]Throughput (Boost License) |
Over 7Gbps |
Over 4Gbps |
Over 4Gbps |
Over 2Gbps |
Over 2Gbps |
1.5Gbps |
1.2Gbps |
4 |
4 |
3 |
3 |
2 |
2 |
||
Total onboard WAN or LAN 10Gbps ports |
2 |
- |
- |
- |
- |
- |
- |
4 |
4 |
3 |
2 |
2 |
2 |
||
4 |
4 |
3 |
2 |
1 |
1 |
||
3 |
0 |
2 |
1 |
0 |
0 |
||
2 |
0 |
1 (assumes no singlewide SM-X modules installed) |
0 |
0 |
0 |
||
3 |
3 |
3 |
2 |
2 |
2 |
||
Yes |
Yes |
Yes |
Yes |
Yes |
No |
||
1 |
1 |
1 |
1 |
1 |
No |
||
Default memory double-data-rate 3 (DDR3) error-correction-code (ECC) DRAM (Combined control/services/data planes) |
NA |
NA |
NA |
4 GB |
4 GB |
4 GB |
4GB |
Maximum memory DDR3 ECC DRAM (Combined control/services/data planes) |
NA |
NA |
NA |
16 GB |
16 GB |
8 GB |
4GB |
Default memory DDR3 ECC DRAM (data plane) |
4 GB |
2 GB |
2 GB |
NA |
NA |
NA |
NA |
Maximum memory DDR3 ECC DRAM (data plane) |
4 GB |
2 GB |
2 GB |
NA |
NA |
NA |
NA |
8 GB |
4 GB |
NA |
NA |
NA |
NA |
||
32 GB |
16 GB |
NA |
NA |
NA |
NA |
||
8 GB |
8 GB |
4 GB |
4 GB |
4 GB |
8GB |
||
32 GB |
32 GB |
16 GB |
16 GB |
8 GB |
8GB |
||
2 |
2 |
2 |
1 |
1 |
1 |
||
1 |
1 |
1 |
1 |
1 |
0 |
||
1 |
1 |
1 |
1 |
1 |
1 (combo CON/AUX port) |
||
1 |
1 |
1 |
1 |
1 |
1 (combo CON/AUX port) |
||
Internal: AC, DC and PoE |
Internal: AC, DC, and PoE |
Internal: AC, DC and PoE |
Internal: AC,DC and PoE |
External: AC and PoE |
External AC only |
||
Internal: AC, DC and PoE |
Internal: AC, DC, and PoE |
N/A |
N/A |
N/A |
NA |
||
100 to 240 VAC autoranging |
100 to 240 VAC autoranging |
100 to 240 VAC autoranging |
100 to 240 VAC autoranging |
100 to 240 VAC autoranging |
100 to 240 VAC autoranging |
||
DC Input Voltage Input Voltage Input Current |
48 – 60V 12A Max |
48 – 60V 12A Max |
48 – 60V 12A Max |
NA NA |
24 – 60V 14 - 5A |
NA NA |
NA NA |
47 to 63 Hz |
47 to 63 Hz |
47 to 63 Hz |
47 to 63 Hz |
47 to 63 Hz |
47 to 63 Hz |
||
7.1 to 3.0A |
3 to 1.3A |
7.1 to 3.0A |
3 to 1.3A |
1.5 to 0.6A |
1.5 to 0.6A |
||
60 A peak and less than 5 Arms per half cycle |
60 A peak and less than 5 Arms per half cycle |
60 A peak and less than 12 Arms per half cycle |
60 A peak and less than 5 Arms per half cycle |
90 A peak and less than 3 Arms per half cycle |
90 A peak and less than 3 Arms per half cycle |
||
|
65 |
48 |
42 |
36 |
24 |
||
1000W (no PoE) |
250 (no PoE) |
430 |
250 |
125 |
90 |
||
Maximum power with DC power supply (watts) |
437 (no PoE) |
437 (no PoE) |
437 (no PoE) |
437 (no PoE) |
250 (no PoE) |
|
|
1000 with PoE redundant 1450 with PoE boost no redundancy |
1450 with PoE boost no redundancy |
500 with PoE redundant 1000 with PoE boost no redundancy |
990 |
530 |
260 |
NA (No PoE Support) |
|
Maximum endpoint PoE power available from PoE power supply (watts) |
500 W with optional redundancy |
250 W with optional redundancy |
500 |
250 |
120 |
NA (No PoE Support) |
|
950 W no redundancy |
500 W no redundancy |
N/A |
N/A |
N/A |
NA (No PoE Support) |
||
Sizes and Weights |
|||||||
3.5 x 17.25 x 18.5 in 88.9 x 438.15 x 469.9 mm) |
(88.9 x 438.15 x 469.9 mm) |
1.73 x 17.25 x 19.97 in (43.9 x 438.15 x 507.2 mm) |
3.5 x 17.25 x 18.5 in (88.9 x 438.15 x 469.9 mm) |
1.75 x 17.25 x 17.25 in (44.45 x 438.15 x 438.15 mm) |
1.75 x 14.55 x 11.60 in (44.55 x 369.57 x 294.64 mm) |
1.72 x 12.7 x 10" (43.7 x 322.6 x 254 mm) |
|
External Power Supply Dimensions (H x W x D) |
N/A |
N/A |
N/A |
N/A |
N/A |
2.95 x 1.18 x 6.10 in (75 x 30 x 155 mm) |
37 x 73 x 152 mm (Phihong mfg PN: AA90U-120A-R) 36.5 x 67 x 155 mm (Delta mfg PN: ADP90GR BA) |
Shipping Box Dimensions (H x W x D) |
9.75 x 22.25 x 26 in (24.76 x 56.51 x 66.04 mm) |
9.75 x 22.25 x 26 in (24.76 x 56.51 x 66.04 mm) |
7.88 x 22.25 x 28.75 in (200.2 x 565.1 x 730.25 mm) |
9.75 x 22.25 x 26 in (24.76 x 56.51 x 66.04 mm) |
7.125 x 22.75 x 22.5 in (180.98 x 577.85 x 571.5 mm) |
7.0 x 21.5 x 16.125 in (177.8 x 546.1 x 409.6 mm) |
4.13 x 18.25 x 12.94" (104.9 x 463.6 x 328.7 mm) |
3 Rack Units (3RU) |
1 Rack Units (1RU) |
2 Rack Units (2RU) |
1 Rack Unit (1RU) |
1 Rack Unit (1RU) |
1 Rack Unit (1RU) |
||
Included |
Included |
Included |
Included |
Included |
Optional |
||
Optional |
Optional |
Optional |
Optional |
N/A |
NA |
||
No |
Yes |
No |
Yes |
Mounting holes under chassis |
Yes |
||
|
N/A |
28.8 lb (13.1 kg) |
N/A |
N/A |
NA |
||
Weight with 1 1,000-WAC power supply+ 1 PoE power module (no other modules) |
|
N/A |
29.0 lb (13.2 kg) |
N/A |
N/A |
NA |
|
Weight with AC PS (no modules) |
|
N/A |
18.5 lb (8.4 kg) |
N/A |
13.5 lb (6.2 kg) |
7.7 lb (3.5 kg) + 1.2 lb (0.66 kg) external PS |
7.1 lb (3.22kg) |
Weight with DC PS (no modules) |
|
28.8lb (13.1kg) |
28.8lb (13.1kg) |
28.8lb (13.1kg) |
13.5 lb (6.2 kg) |
|
|
Weight with AC PS with POE (no modules) |
|
N/A |
18.6 lb (8.4 kg) |
N/A |
14.1 lb (6.4 kg) |
N/A |
NA |
|
22.4 lb (10.2 kg) |
37.7 lb (17.1 kg) |
16.1 lb (7.3 kg) |
9.14 lb (4.2 kg) + 1.2 lb (0.66 kg) external PS |
8.11 lb (3.68kg) |
||
Packaging Weight |
|
6.4 lb (2.9 kg) |
5.9 lb (2.7 kg) |
6.4 lb (2.9 kg) |
4.6 lb (2.1 kg) |
2.2 lb (1 kg) |
1.28 lb (0.58kg) |
Airflow |
I/O side to bezel side |
I/O side to bezel side |
I/O side to bezel side |
I/O side to bezel side |
I/O side to bezel side |
Right I/O side to Left I/O side |
I/O side to bezel side |
480770 |
512970 |
566310 |
587250 |
593270 |
593270 |
||
Environmental Specifications |
|||||||
32 to 104ºF |
32 to 104ºF |
32 to 104ºF (0 to 40ºC) |
32 to 104ºF (0 to 40ºC) |
32 to 104ºF (0 to 40ºC) |
32 to 104ºF (0 to 40ºC) |
||
Altitude (China) |
0 – 6,560 ft. (0 – 2,000 m) |
0 – 6,560 ft. (0 – 2,000 m) |
0 – 6,560 ft. (0 – 2,000 m) |
0 – 6,560 ft. (0 – 2,000 m) |
0 – 6,560 ft. (0 – 2,000 m) |
0 – 6,560 ft. (0 – 2,000 m) |
0 – 6,560 ft. (0 – 2,000 m) |
(Rest of the world) |
0 – 10,000 ft. (0 – 3,050 m) |
0 – 10,000 ft. (0 – 3,050 m) |
0 – 10,000 ft. (0 – 3,050 m) |
0 – 10,000 ft. (0 – 3,050 m) |
0 – 10,000 ft. (0 – 3,050 m) |
0 – 10,000 ft. (0 – 3,050 m) |
0 – 10,000 ft. (0 – 3,050 m) |
Short Term Temperature upto 6560ft per NEBS GR-63-CORE |
NA |
NA |
NA |
NA |
32° to 131° (0° to 55° C) (for ISR4331-DC version) |
NA |
NA |
5% to 85% |
5% to 85% |
5% to 85% |
5% to 85% |
5% to 85% |
5% to 85% |
||
5% to 90%, not to exceed 0.024 kg water/kg of dry air |
5% to 90%, not to exceed 0.024 kg water/kg of dry air |
5% to 90%, not to exceed 0.024 kg water/kg of dry air |
5% to 90%, not to exceed 0.024 kg water/kg of dry air |
5% to 90%, not to exceed 0.024 kg water/kg of dry air |
5% to 90%, not to exceed 0.024 kg water/kg of dry air |
||
Sound pressure (Typical/ |
50.6/73.1 dBA |
54.3/79.1 dBA |
50.6/73.1 dBA |
52.8/74.8 dBA |
24.2/51.9 dBA |
28.5/53 dBA |
|
Sound power (Typical/ |
58.2/78.8 dBA |
57.2/80.8 dBA |
58.2/78.8 dBA |
61.2/81.6 dBA |
31.9/59.9 dBA |
41 / 68 dBA |
|
-40 to 158ºF |
-40 to 158ºF |
-40 to 158ºF |
-40 to 158ºF |
-40 to 158ºF |
-40 to 158ºF |
||
5% to 95% |
5% to 95% |
5% to 95% |
5% to 95% |
5% to 95% |
5% to 95% |
||
15,584 ft (4750m) |
15,584 ft (4750m) |
15,584 ft (4750m) |
15,584 ft (4750m) |
15,584 ft (4750m) |
15,584 ft (4750m) |
||
UL 60950-1 CAN/CSA C22.2 No. 60950-1 EN 60950-1 AS/NZS 60950-1 IEC 60950-1 |
UL 60950-1 CAN/CSA C22.2 No. 60950-1 EN 60950-1 AS/NZS 60950-1 IEC 60950-1 |
UL 60950-1 CAN/CSA C22.2 No. 60950-1 EN 60950-1 AS/NZS 60950-1 IEC 60950-1 |
UL 60950-1 CAN/CSA C22.2 No. 60950-1 EN 60950-1 AS/NZS 60950-1 IEC 60950-1 |
UL 60950-1 CAN/CSA C22.2 No. 60950-1 EN 60950-1 AS/NZS 60950-1 IEC 60950-1 |
UL 60950-1 CAN/CSA C22.2 No. 60950-1 EN 60950-1 AS/NZS 60950-1 IEC 60950-1 |
||
47 CFR, Part 15 ICES-003 Class A EN55032 Class A CISPR32 Class A AS/NZS CISPR 32 Class A VCCI V-3 CNS 13438 EN 300-386 EN 61000 (Immunity) EN 55024, CISPR 24 KN22, KN24 |
47 CFR, Part 15 ICES-003 Class A EN55032 Class A CISPR32 Class A AS/NZS CISPR 32 Class A VCCI V-3 CNS 13438 EN 300-386 EN 61000 (Immunity) EN 55024, CISPR 24 KN22, KN24 |
47 CFR, Part 15 ICES-003 Class A EN55032 Class A CISPR32 Class A AS/NZS CISPR 32 Class A VCCI V-3 CNS 13438 EN 300-386 EN 61000 (Immunity) EN 55024, CISPR 24 KN22, KN24 |
47 CFR, Part 15 ICES-003 Class A EN55032 Class A CISPR32 Class A AS/NZS CISPR 32 Class A VCCI V-3 CNS 13438 EN 300-386 EN 61000 (Immunity) EN 55024, CISPR 24 KN22, KN24 EN 50121-1 EN61000-6-4 EN 50121-4 |
ICES-003 Class A EN55032 Class A CISPR32 Class A AS/NZS CISPR 32 Class A VCCI V-3 CNS 13438 EN 300-386 EN 61000 (Immunity) EN 55024, CISPR 24 KN22, KN24 |
ICES-003 Class A EN55032 Class A CISPR32 Class A AS/NZS CISPR 32 Class A VCCI V-3 CNS 13438 EN 300-386 EN 61000 (Immunity) EN 55024, CISPR 24 KN22, KN24 |
||
Telecom |
T1 IC CS-03:2004 TIA-968-B:2009 HKTA 2028:2010 HKTA 2017:2010 HKTA 2015: 2006 G.703:2001 ID0002:2007 IS6100:2004 DSPR Gray Book:2000 DSPR Technical Condition: 2004 E1 AS/ACIF S016: 2001 AS/ACIF S038: 2001 G.703:2001 TBR 4:1995 TBR 12:1993 TBR 13:1996 RRA 2009-38 (RRL 2005-96) IDA TS DLCN:2011 IDA TS ISDN PRA:2005 IS6100: 2004 PTC 220:2008 Ethernet IEEE 802.3 ANSA X3.263 |
T1 IC CS-03:2004 TIA-968-B:2009 HKTA 2028:2010 HKTA 2017:2010 HKTA 2015: 2006 G.703:2001 ID0002:2007 IS6100:2004 DSPR Gray Book:2000 DSPR Technical Condition: 2004 E1 AS/ACIF S016: 2001 AS/ACIF S038: 2001 G.703:2001 TBR 4:1995 TBR 12:1993 TBR 13:1996 RRA 2009-38 (RRL 2005-96) IDA TS DLCN:2011 IDA TS ISDN PRA:2005 IS6100: 2004 PTC 220:2008 Ethernet IEEE 802.3 ANSA X3.263 |
TIA-968-B CS-03 ANSI T1.101 ITU-T G.823, G.824 IEEE 802.3 RTTE Directive Homologation requirements vary by country and interface type. For specific country information, refer to the online approvals data base at: https://www.ciscofax.com/. |
TIA-968-B CS-03 ANSI T1.101 ITU-T G.823, G.824 IEEE 802.3 RTTE Directive Homologation requirements vary by country and interface type. For specific country information, refer to the online approvals data base at: |
TIA-968-B CS-03 ANSI T1.101 ITU-T G.823, G.824 IEEE 802.3 RTTE Directive Homologation requirements vary by country and interface type. For specific country information, refer to the online approvals data base at: https://www.ciscofax.com/. |
TIA-968-B CS-03 ANSI T1.101 ITU-T G.823, G.824 IEEE 802.3 RTTE Directive Homologation requirements vary by country and interface type. For specific country information, refer to the online approvals data base at: |
TIA-968-B CS-03 ANSI T1.101 ITU-T G.823, G.824 IEEE 802.3 RTTE Directive Homologation requirements vary by country and interface type. For specific country information, refer to the online approvals data base at: |
Cisco IOS XE Software |
|||||||
Protocols |
IPv4, IPv6, static routes, Routing Information Protocol Versions 1 and 2 (RIP and RIPv2), Open Shortest Path First (OSPF), Enhanced IGRP (EIGRP), Border Gateway Protocol (BGP), BGP Router Reflector, Intermediate System-to-Intermediate System (IS-IS), Multicast Internet Group Management Protocol Version 3 (IGMPv3), Protocol Independent Multicast sparse mode (PIM SM), PIM Source Specific Multicast (SSM), RSVP, CDP, ERSPAN, IPSLA, Call Home, EEM, IKE, ACL, EVC, DHCP, FR, DNS, LISP, OTV[6], HSRP, RADIUS, AAA, AVC, Distance Vector Multicast Routing Protocol (DVMRP), IPv4-to-IPv6 Multicast, MPLS, Layer 2 and Layer 3 VPN, IP sec, Layer 2 Tunneling Protocol Version 3 (L2TPv3), Bidirectional Forwarding Detection (BFD), IEEE802.1ag, and IEEE802.3ah |
||||||
Encapsulations |
Generic routing encapsulation (GRE), Ethernet, 802.1q VLAN, Point-to-Point Protocol (PPP), Multilink Point-to-Point Protocol (MLPPP), Frame Relay, Multilink Frame Relay (MLFR) (FR.15 and FR.16), High-Level Data Link Control (HDLC), Serial (RS-232, RS-449, X.21, V.35, and EIA-530), and PPP over Ethernet (PPPoE) |
||||||
Traffic management |
QoS, Class-Based Weighted Fair Queuing (CBWFQ), Weighted Random Early Detection (WRED), Hierarchical QoS, Policy-Based Routing (PBR), Performance Routing, and NBAR. |
||||||
Cryptographic Algorithms |
Encryption: DES, 3DES, AES-128 or AES-256 (in CBC and GCM modes); Authentication: RSA (748/1024/2048 bit), ECDSA (256/384 bit); Integrity: MD5, SHA, SHA-256, SHA-384, SHA-512 |